# Action on Loss of Pressure

### No internal source of release

The over-pressure within the enclosure is monitored by a pressure switch/sensor, and a flow-rate switch/sensor, located at the exhaust dust, is used to monitor the rate of flow of the safe gas through the enclosure. Loss of over-pressure or rate of flow will activate either an alarm or shutdown of the internal electrical components, the action taken being dependent on:

1. The EPL requirement of the area in which the system is located;
2. The type of equipment/components within the enclosure.

**IEC 60079-14:2013, Table 18, specifies the action to be taken on loss of pressure as follows:**

| **EPL requirement** | **Enclosure contains equipment not meeting EPL ‘Gc’ requirements without pressurisation** | **Enclosure contains equipment meeting EPL ‘Gc’ requirements without pressurisation** |
| --- | --- | --- |
| **‘Gb’** | **Alarm and switch off ^a** | **Alarm ^b** |
| **‘Gc’** | **Alarm^b** | **No action** |

**a** - **If automatic switch-off would introduce a more dangerous condition, other precautionary measures should be taken, for example, duplication of protective gas supply.**

**b** - **If the alarm operates, immediate action should be taken to restore the integrity of the system.**

### With an internal source of release

The action to be taken depends on the Zone, type of equipment and the type/severity of the release. (Details are beyond the scope of these notes).